SOP ON OPERATION AND CLEANING OF INSECTICUTER
OBJECTIVE : To lay down the procedure for operation and Cleaning of Insecticuter.
SCOPE : This SOP is applicable for the operation and Cleaning of Insecticuter mounted for the protection of ancillary area with insects in the plant.
RESPONSIBILITY: Officer/ Manager- Personnel & Administration – To ensure proper cleaning and operation of Insecicuter.
ACCOUNTABILITY: To ensure implementation of procedure
PROCEDURE:
Put “OFF” main switch of Insecticuter.
Remove the power plug of Insecticuter.
Remove the tray from the bottom side of Insecticuter.
Count the insects put into a polythene bag, properly label and sent for destruction.
Clean the unit and tray by a dry cloth.
If any stain is observed, clean with 70 % IPA.
After completion of cleaning fix the tray back in place.
Check the tube rod for cleaning if any visible dust is found, clean with dry cloth carefully.
If tube rods are not working, inform Engineering department for replacement.
Make the electrical connection by putting connecting wire in the socket and switch on the the
The number of dead insect should not be more than 20 in Routine session and should not be more than 30 in monsoon
If the dead insect found more than acceptance then the frequency on pest control shall be increase.
Keep the Insecticuter always on except of time of cleaning.
Frequency:
For cleaning of Insecticuter is weekly.
For replacement of ultraviolet tube rod is once in six month