Personnel EUGMP- Annex-1

Personnel EUGMP- Annex-1 Question 1. The manufacturer must ensure there are sufficient personnel who are: A. Newly hiredB. Qualified, trained, and experiencedC. Working part-timeD. Only externally certifiedAnswer: B Question 2. Personnel must be trained in the manufacture and testing of: A. Veterinary products onlyB. Sterile productsC. CosmeticsD. Medical devicesAnswer: B Question 3. Only the ______ number of … Read more

Questions & Answers Utilities, Water Systems, Steam, Gases, and Heating/Cooling Systems EUGMP- Annex-1

Questions & Answers Utilities, Water Systems, Steam, Gases, and Heating/Cooling Systems EUGMP- Annex-1 Question 1. The level of controls applied to utility systems should be based on: A. Historical dataB. Auditor preferenceC. Risk to product qualityD. Cost of maintenance ANSWER – C Question 2. Utility system impact must be assessed and documented as part of the: A. Preventive … Read more

Terminally Sterilized Products EUGMP- Annex-1

Terminally Sterilized Products EUGMP- Annex-1 Question 1. Preparation of components and materials for terminally sterilized products should be performed in at least: A. Grade AB. Grade BC. Grade CD. Grade DAnswer: D Question 2. The purpose of using at least a Grade D room for preparation is to limit: A. Temperature deviationB. Microbial, endotoxin/pyrogen, and particle contaminationC. … Read more

Examples of operations and grades for aseptic preparation and processing operations EUGMP- Annex-1

Examples of operations and grades for aseptic preparation and processing operations EUGMP- Annex-1 Question 1. Which activity is performed in Grade A? A. Cleaning of equipmentB. Aseptic compounding and mixingC. Preparation of solutions to be filteredD. Handling of components after cleaningAnswer: B Question 2. Aseptic assembly of filling equipment belongs to which grade? A. Grade DB. … Read more

Aseptic Preparation and Processing in Pharma EUGMP- Annex-1

Aseptic Preparation and Processing in Pharma EUGMP- Annex-1 Question 1. The aseptic process should be: A. Informal and flexibleB. Clearly definedC. Performed without documentationD. Determined only by productionAnswer: B Question 2. Risks associated with the aseptic process should be: A. Ignored unless criticalB. Identified, assessed, and controlledC. Controlled only by QAD. Evaluated only onceAnswer: B Question 3. Accepted … Read more

Sterile Product Finishing EUGMP- Annex-1

Sterile Product Finishing EUGMP- Annex-1 Questions 1. Open primary packaging containers must be maintained under which conditions? A. Grade BB. Grade CC. Grade AD. Grade DAnswer: C Questions 2. Final containers should be closed using: A. Any available methodB. Manually approved methodsC. Appropriately validated methodsD. Vendor-recommended methods onlyAnswer: C Questions 3. Containers closed by fusion include: A. … Read more

Questions and answers of Incident Procedure in Pharma EUGMP- Annex-1

Questions and answers of Incident Procedure in Pharma EUGMP- Annex-1 Question 1. What is an incident as per the definition? A planned deviation B. An unplanned or uncontrolled event C. A customer complaint D. A routine process step Answer: B Question 2. Incidents occur due to: A. Market complaints B. System failure, equipment breakdown, or manual … Read more

Sterilization by Heat EUGMP- Annex-1

 Sterilization by Heat EUGMP- Annex-1 1. Each heat sterilization cycle should be recorded: A. Only in handwritten logsB. Either electronically or by hardcopyC. Only when deviations occurD. Only if requested by inspectorsAnswer: B 2. Control and monitoring systems for heat sterilisation should include: A. No redundancyB. Only visual indicatorsC. Safeguards and/or redundancy to detect non-conforming … Read more

Sterilization EUGMP- Annex-1

Sterilization EUGMP- Annex-1 Questions 1. Terminal sterilization is preferred because: A) It is faster than filtration B) It provides greater sterility assurance C) It requires no validation D) It uses fewer resources Answer: B Questions 2. When terminal sterilisation is not possible, one alternative is: A) UV sterilisation B) Post-aseptic processing terminal heat treatment C) Chemical … Read more

Moist Heat Sterilization EUGMP- Annex-1

Moist Heat Sterilization EUGMP- Annex-1 1. Moist heat sterilization can be achieved using: A) Dry hot air only B) Steam (direct or indirect) C) UV radiation D) Gamma radiation Answer: B 2. Superheated water systems may be used for: A) Metal instruments B) Containers easily damaged by other cycles C) Rubber stoppers only D) Paper … Read more