PROTOCOL TO EVALUATE EFFICACY OF UV GERMICIDAL LAMP WITH KNOWN MICROORGANISM

PROTOCOL TO EVALUATE EFFICACY OF UV GERMICIDAL LAMP WITH KNOWN MICROORGANISM OBJECTIVE The objective of this study is to determine the efficacy of UV germicidal lamp of Laminar air flow and pass box with known microorganism. This ensure that the UV is effective enough to kill the microorganisms on exposure to …

Read More »

Unit Dose Sampling Procedure for Blend Uniformity

Unit Dose Sampling Procedure for Blend Uniformity OBJECTIVE To lay down the procedure for collecting unit dose blend samples for evaluation of blend uniformity so as to ensure accurate and consistent sampling. RESPONSIBILITY : Officer – Quality Assurance to collect the samples. Head of Quality Assurance to ensure compliance. PROCEDURE: …

Read More »

Worst case identification for cleaning validation

Worst case identification for cleaning validation OBJECTIVE: Objective of this SOP is to provide the procedure to be followed during worst case identification for cleaning validation. It also includes updating of API solubility – potency matrix, calculation of acceptable residue levels during cleaning validation. SCOPE: This SOP covers the worst …

Read More »

Prospective Process Validation

PROCESS VALIDATION PROTOCOL OF PARACETAMOL 500 MG CAPLTES Batch size: 8,000,00Tablets (480.00 kg) ,Shelf life: 36 Months, Reason for validation: Introduction of New Product at Site (8.0Lac.) Table of Contents Pre- approval Objective Scope Responsibilities Reference documents Key equipment / instrument detail (qualification / calibration) Product detail Master formula Process description Process …

Read More »

VALIDATION MASTER PLAN

VALIDATION MASTER PLAN CONTENTS SR. NO. CONTENTS PAGE NO. 1 APPROVAL 2 INTRODUCTION 3 VALIDATION POLICY 4 OBJECTIVE 5 SCOPE 6 VALIDATION RESPONSIBILITIES 6.1 Validation Team Constitution 7 FACILITY DESCRIPTIONS AND DESIGN 7.1 General Description and Design Concept 7.2 Description of Products 7.3 Description of Process 7.4 Description of Equipments …

Read More »

USER REQUIREMENT SPECIFICATION OF PRESSURE VESSEL

USER REQUIREMENT SPECIFICATION OF PRESSURE VESSEL Equipment No’s.  Description Use Field Identification:  To be installed in medicament preparation room in soft gelatin block. (i) Room Temperature NMT 25ºC and RH NMT 60 % (ii)  Non flame proof. Salient Features Material of Construction All the contact parts preferably should be of …

Read More »

SOP for operation of Metal Detector for automatic capsule filling machine

SOP for operation of Metal Detector for automatic capsule filling machine Objective: To lay down a procedure for operation of metal detector. Scope: This SOP is applicable for the operation of metal detector to the formulation plant of  PHARMACEUTICAL Company. Responsibility: Production Operator/ Technician – For operation of the machine. …

Read More »

Installation Qualification for Pass Box

Installation Qualification for Pass Box TABLE OF CONTENTS Approval Objective Responsibility Equipment Identification Equipment location Documentation Pre-requisite of Installation Qualification Installation Qualification Procedure System Description Procedure Installation Check List Inspection Check list Leveling and Alignment Material of Construction Check Points Guarantee / Warrantee Certificates Drawing Execution Identification of Standard Operating …

Read More »

Operational Qualification for Pass Box

Operational Qualification for Pass Box The static pass through hatch is used wherever transfer of material is required in between the clean room and non clean room or in between the clean room if different classification. The product is provided with door interlocking system and minimum component of germicidal light …

Read More »

MANAGEMENT REVIEW OF QUALITY METRICS

MANAGEMENT REVIEW OF QUALITY METRICS Management review of quality Metrics procedure provides Monthly/ Quarterly Management Review and assessment of the performance of Quality and GMP systems. This document describes the activities of the Quality review meeting. SCOPE OF MANAGEMENT REVIEW OF QUALITY METRICS: This procedure applies to all facilities related …

Read More »

Temperature Mapping

Temperature Mapping Temperature mapping involves systematically assessing temperature changes within a specific area. This area ranges from warehouses for storing temperature-sensitive pharmaceuticals to critical laboratory incubators needed for successful experiments. The goal is to detect potential areas of excessive heat or cold that may pose a risk to the quality …

Read More »

Types of liquid column chromatography( HPLC)

Types of liquid column chromatography( HPLC) The type of liquid column chromatography (HPLC) can be classified on the nature of the stationary phase and the separation process. There Can be classified into three types Adsorption chromatography Ion-exchange chromatography Size exclusion chromatography Adsorption chromatography In adsorption chromatography the stationary phase is an …

Read More »

Process analytical technology (PAT) — A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance

Process analytical technology (PAT) — A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance PAT FRAMEWORK PAT to be a system for designing, analyzing, and controlling manufacturing through timely measurements (i.e., during processing) of critical quality and performance attributes of raw and in-process materials and processes, with the goal of ensuring final …

Read More »

SOP for environmental  monitoring of air

SOP for environmental  monitoring of air OBJECTIVE  :To lay down a procedure for environmental  monitoring of air. SCOPE  :This SOP shall provide the procedure for monitoring the viable air borne count . RESPONSIBILITY :Microbiologist ACCOUNTABILITY Manager QC/QA PROCEDURE  The microbial environmental conditions  shall be monitored as per defined frequency and …

Read More »

DESIGN QUALIFICATION (DQ) of Blister Packing Machine (BQS)

DESIGN QUALIFICATION (DQ) of Blister Packing Machine (BQS) TABLE OF CONTENT Objective Scope Responsibility Machine description Technical specification Technical specifications and make of sub-components/ bought out items. Details of Utilities Identification of components for calibration Material of construction of all components Safety features and alarms FAT procedure Change control procedure …

Read More »

PERFORMANCE QUALIFICATION PROTOCOL OF PURE NITROGEN

PERFORMANCE QUALIFICATION PROTOCOL Pure nitrogen is obtained by removing oxygen from air in two stages. Oil free compressed air is first dehumidified (anhydrous alumina is the desiccant) and is passed through a 0.01 micron filter and then column of Carbon Molecular Sieve (CMS) where oxygen is adsorbed from this column. …

Read More »

Pass Box for Clean room and it validaton

Pass Box for Clean room and it validation Definitions of Pass Box: Pass Box is specifically designed that aids in the material transfer without much personnel movement in clean rooms and also work like a barrier between classified and unclassified area.two types of pass box is used in pharmaceutical industry that …

Read More »

Reynolds number and its importance in water system

Reynolds number and its importance in water system Purified water is the most used ingredient in pharmaceutical industries its used directly for the drug manufacturing process and also used for equipment’s cleaning. Purified water and Purified water generation and distribution system is one of the most important and critical part of a pharmaceutical facility and …

Read More »

SOP on operation and cleaning of analytical balance used in aseptic area (Sartorious).

SOP on operation and cleaning of analytical balance used in aseptic area (Sartorious) Objective: To lay down a procedure for operation and cleaning of analytical balance used in the aseptic area (Make: Sartorious). Scope The SOP describes the procedure for operation and cleaning of analytical balance used in the aseptic …

Read More »

Procedure for calibration of balance XS 204 DR.

  To lay down a procedure for calibration of Weighing Balance XS – 204 DR SCOPE This Standard Calibration Procedure (SOP) is applicable in quality control area. RESPONSIBILITY Quality Control Officer/ Executive ACCOUNTABILITY Head –Quality Assurance PROCEDURE PRE STARTUP Check the cleaning of the weighing balance especially pan & display …

Read More »