INPROCESS CONTROL OF CAPSULE MANUFACTURING

OBJECTIVE: To lay down the procedure for In process Control of Capsule Manufacturing. SCOPE: This SOP covers the responsibility and procedure for In process control during capsule manufacturing. RESPONSIBILITY: In process Quality Assurance Executive/Officer. ACCOUNTABILITY: Quality Assurance Manager. PROCEDURE: Carry out line clearance at each stage of operation prior to …

Read More »

PROCEDURE FOR CALIBRATION OF REFRIGERATOR

OBJECTIVE:To describe the calibration procedure for distribution of temperature within the chamber of Refrigerator. SCOPE: his SOP shall be applicable for Calibration of Refrigerator at Pharmaceutical Industries. RESPONSIBILITY :             Quality Control Executive/Officer. ACCOUNTABILITY Head Quality Control PROCEDURE : Operate the refrigerator as per Standard …

Read More »

List of Documents required for Quality Control Departments (GMP & GLP Compliances)

Pharmaceutical GuidanaceMr. Shiv Kumar is the Author and founder of pharmaceutical guidance, he is a pharmaceutical Professional from India having more than 14 years of rich experience in pharmaceutical field. During his career, he work in quality assurance department with multinational company’s i.e Zydus Cadila Ltd, Unichem Laboratories Ltd, Indoco …

Read More »

SAMPLING OF PACKING MATERIALS

OBJECTIVE To lay down a procedure for sampling of packaging materials. SCOPE To describe the procedure for sampling of Primary packing materials i.e. Aluminium Foil, Blister Aluminium Foil, PVC Film etc. and secondary packing materials i.e. Cartons, labels, Leaflet shipper etc. RESPONSIBILITY Quality Control Executive/Officer ACCOUNTABILITY Quality Assurance Manager PROCEDURE …

Read More »

STABILITY STUDY PROTOCOL

STABILITY STUDY PROTOCOL THIS PROTOCOL IS: Lisinopril and Hydrochlorothiazide tablets 10+12.5 mg CONTENTS: Each uncoated tablet contains: Lisinopril dihydrate equivalent to Lisinopril 10mg Hydrochlorothiazide                                           12.5mg SHELF LIFE: 24 months DOSAGE FORM: Tablet MANUFACTURED AT:   TYPE OF STABILITY STUDIES: Accelerated stability studies 40 + 20C / 75 + …

Read More »

SOP on the Transfer of Technology for Analytical Method

Objective: To lay down the procedure for Transfer of Technology for Analytical Methods. Scope: This procedure is applicable for Transfer of technology for Analytical Methods from ARD to Formulation Unit. Responsibility: Responsibility of Sending Unit (ARD ) are : Preparation of Technology transfer Protocol for Analytical Method transfer. Execution of …

Read More »

SOP on cleaning and operating procedure of bursting strength tester

Objective: To lay down the cleaning & operating procedure of bursting strength tester. Scope: This SOP is applicable for the cleaning & operating procedure of bursting strength tester in quality control laboratory. Responsibilities: Chemist or above of QC laboratory in Packaging material Quality Control section is responsible for carrying out …

Read More »

Procedure for operation of pH / CONDUCTIVITY METTLER (PICO)

OBJECTIVE To lay down the procedure for operation of pH / Conductivity meter (PICO) SCOPE To ensure that the instrument performs satisfactory and gives accurate and reproducible data. This SOP shall be applicable for the pH / Conductivity meter (PICO). RESPONSIBILITY Quality Control Executive/Officer. ACCOUNTABILITY Quality Control Manager. PROCEDURE PROCEDURE …

Read More »

Operating procedure for milli Q water system

OBJECTIVE To lay down the procedure for Operation of Milli Q water system, Make Millipore. SCOPE  This SOP shall provide the Operating procedure of Milli – Q water system of quality control department. RESPONSIBILITY  Officer/ Executive – Quality Control ACCOUNTABILITY Head QC/QA PROCEDURE OPERATION OF ELIX –10 Switch on Elix …

Read More »

Procedure for operation of SAS SUPER 100 AIR SAMPLER

OBJECTIVE To lay down a procedure for operation of SAS SUPER 100 Air sampler. SCOPE This SOP shall be applicable for viable air monitoring. RESPONSIBILITY Microbiologist ACCOUNTABILITY Head QC/QA PROCEDURE PRE START UP Remove the aspirating head. Insert an identified, closed contact plate and remove the lid of the plate. …

Read More »