SOP for Cleaning and Sanitization of Drain Point.
- Objective:
- To lay down a procedure for cleaning and sanitization of drain point.
- Scope:
- This SOP is applicable for cleaning and sanitization of drain point.
- Responsibility:
- Production Officers / Executive shall be responsible for follow the procedure mentioned in this SOP.
- Accountability:
- Production Head and QA head shall be accountable for compliance of SOP.
- Abbreviations
- SOP : Standard Operating Procedure.
- Ltr.:Liter
- WFI : Water for Injection
- Procedure:
- Note: the disinfectant used as per the rotation cycle for cleaning and sanitization of the area shall be used for the drain
- Cleaning and sanitization of drain:
- The drain covering mesh shall be cleaned by wire brush.
- If water clogging takes place, the mesh shall be opened and the drains are cleaned by wire brush.
- Drain the disinfectant solution daily through each drain point (approximately 1Ltr. / drain).
- Close the drain by the mesh & cover.
- Record the details of cleaning and sanitization of drain in Annexure -1 and get checked by concerned supervisor / officer.
Annexure-1
Cleaning and sanitization of drain point
Disinfectant solution used ………………….. Date: ……………………
Sr. | Location of drain | Cleaning Done by | Sanitization Done by | Checked By | Remarks |
1. | Garment washing room.
(Drain Point – I) |
||||
2. | Vial washing & sterilization room (Drain point – II) | ||||
3. | Bung Processor cum steam sterilizer (Drain point – III) | ||||
4. | Equipment washing & sterilization (Drain Point – IV) | ||||
5. | In-process quality control room (Drain point – V) |
- Distribution
- Master copy – Quality Assurance
- Controlled copies- Quality Assurance, Production, Quality Control
- History
Date Revision Number Reason for Revision
– 00 New SOP